USING YOUR SENTRY SYSTEM™ CONTROL
7
Power Interrupt – The Sentry control indicator LED will
display "Power Failure", to notify you that a power out-
age has occurred. It is recommended that you check
the condition of your stored items.
The Sentry alarms may be enabled or disabled by
pressing and holding the SET key for 5 seconds.
Conrmation of turning the Sentry alarms on or off will
be given by the control beeping 3 times. When Sentry
alarms are enabled, the display will show green "ON".
When Sentry alarms are disabled, the display will show
amber "OFF".
Sabbath Mode:
Your product may be placed into Sabbath mode if desired.
During this time the displays, audible alarms/keypad con-
rmations, and lights will be disabled. To activate Sabbath
mode, press and hold the "Set" keypad while pressing the
"°F/°C" keypad four(4) times within seven(7) seconds. The
display will conrm activation by "ashing" SA seven(7)
times before blanking the display. Sabbath mode will auto-
matically deactivate after 72 hours, or you may cancel it at
any time by repeating the keypad activation sequence. All
control functions and set-point temperatures will remain as
they were prior to entering Sabbath mode.
Turning Off Refrigeration:
You may turn off the refrigeration system in your product for
prolonged cleaning or times when cooling is not required
such as an extended vacation, or absence from a seasonal
residence. To shut off the refrigeration system press and
hold the "ON/OFF" keypad for 5 seconds. Conrmation
will be indicated by the control display going blank. Interior
lights will continue to function for your convenience. To
resume refrigeration, press and hold the "ON/OFF" keypad
for 5 seconds.
Important: Although this action shuts down the refrigeration
system, it does not remove power from the unit. Always
remember to unplug the unit, or remove power from the
receptacle, when servicing the product.
Error Codes:
The Sentry control system continually monitors your prod-
ucts critical refrigeration system components for proper
operation. If a components operating parameters do not
meet normal specications, the control display will indicate
one of the following faults:
E1 - Compressor
E2 - Condenser Fan Motor
E3 - Upper Compartment Sensor
E4 - Lower Compartment Sensor
If any of these errors occur, a service call by a qualied ser-
vice technician is required, (see Trouble Shooting section
for details).