USING YOUR MICROSENTRY™ REFRIGERATOR CONTROL
Temperature Sensor Fault: If the controller
detects that the temperature sensor is
not properly funconing, a temperature
sensor alarm will sound. “E1” will ash on the display, and an
alarm will sound. Please call AGA MARVEL Customer Service or
your dealer if this error code is displayed.
Condenser Needs Cleaning: When the refrig-
erator has reached the recommended amount
of run me for a condenser cleaning, “cL
will ash on the display as a reminder to clean the condenser.
To clear the alarm:
1) Press and quickly release the SET key 7 mes.
cnd” will be displayed on the screen.
2) While “cnd” is displayed, press and hold the SET key.
The display will show the number of weeks the con-
denser has been operang.
3) Connue to hold the SET key, then press and release the
ON/OFF key. The number shown on the display will be
reset to 00.
4) Release the SET key.
5) The display will return to normal operaon aer a few
seconds with no key presses.
See the “care and cleaning” secon for cleaning instrucons.
Alarm Mute
Press any key to mute the audible poron of an alarm.
NOTE-This acon will only mute the alarm. If the condion that
caused the alarm connues, the alarm code will connue to ash
and will sound for 20 seconds every 60 minutes.

To turn refrigerator o, press and hold “ON/OFF” buon for
three (3) seconds. “OFF” will appear on the display.

Refer to Appendix A for details on addional features available.
Orange Wire / NC
Blue Wire / COM
Yellow Wire / NO
Remote Alarm Connecons
Maximum Contact Rang: 125-250V 5A
Remote Alarm Relay
Remote Alarm Interface
The auxiliary output of the control is programmed to monitor
alarm condions. An outboard relay connected to the auxiliary
output provides a set of dry contacts which are designed to be
used as a remote alarm monitoring interface. Alarm funcons
monitored are Door Ajar, High/Low Temperature, and Power Fail-
ure. -
 It is recommended the remote monitoring device(s) have
an uninterruptable power source. (See Figure 9 and 10 below).
NOTE
However it must be noted the alarm will connue to sound unl
the alarm condion has been reced.
Figure 9
8
Blue
Yellow
DC Power
Supply
+
Buzzer
Figure 10
Seitenansicht 7