Step 9: Secure overlay panel to the door.
With the #8 wood screws provided fasten the overlay
panel to the door. (See Figure 12).
Step 10: Install lock cam (Models with locks only).
Attach the lock cam to the back of the lock assembly with
the phillips head machine screw provided. Orient the lock
cam vertically when installing on the lock.
Step 11: Install door gasket
Press the door gasket into the door channel. Make
certain the gasket corners are fully inserted. If applicable
insert the key into the lock and make certain the lock
operates properly.
Step 12: Install the door
Install the top and bottom hinge adapter bushings back
into the hinge adapters that were removed in step 6.
Install the door by reversing the procedure from step 2.
Install the top hinge pin so the screw head is flush with
the top surface of the hinge. If applicable insert key into
lock and verify the lock cam works properly with the
catch bracket on the front of the refrigerator cabinet.
Top hinge pin
Top door hinge
adapter
Top hinge adapter
bushing
Top hinge
Bottom door
hinge adapter
Bottom hinge
adapter bushing
Bottom hinge pin
Bottom hinge
with cam
Figure 11
Right hand
hinges shown
Clearance hole through
door gasket channel
#8 Wood Screw
Figure 12
Back of door
Condenser Air Flow
The machine compartment located beneath the cabinet
does not require frequent cleaning; however, satisfactory
performance depends on adequate ventilation. Be sure
nothing obstructs the required air flow openings in front of
the cabinet. At least once or twice a year, brush or vacuum
lint and dirt from the front grille openings. See Figure 1 on
page 3.
Cabinet
The painted cabinet can be washed with either a mild soap
and water and thoroughly rinsed with clear water. NEVER
use abrasive scouring cleaners.
Interior
Wash interior compartment with mild soap and water. Do
NOT use an abrasive cleaner, solvent, polish cleaner or
undiluted detergent.
Care of Unit
Avoid leaning on the door, you may bend the door 1.
hinges or tip the unit.
Exercise caution when sweeping, vacuuming or mop-2.
ping near the front of the unit. Damage to the grille
can occur.
Periodically clean the interior of the unit as needed.3.
Periodically check and/or clean the front grille as 4.
needed.
Replacing the light bulb.
Unplug the power cord from the wall receptacle.1.
Open the cabinet door.2.
Remove the 3 screws on the front face of the light lens.3.
Remove the lens.4.
Unscrew the existing bulb and replace with an equiva-5.
lent 15 watt, intermediate base appliance bulb. Do not
replace with a bulb higher than 15 watts.
Reassemble parts and plug in power cord.6.
To clean the light assembly, disconnect the power cord and
wipe the assembly with a mildly damp cloth. Dry the unit
completely before connecting the power cord.
CARE AND CLEANING